Valves — Installation Instructions

PP20621

Angle Valve Inlet 5/8" O.D.(1/2" nom. copper) Outlet 1/2"O.D. Chrome

Pp67pc
Instructions:
  1. Turn off water supply leading to work area.
  2. Open faucet or flush toilet to remove water existing in line.
  3. Remove old valve.
  4. Slide flange over copper stub-out to wall.
  5. Slide large compression nut and sleeve onto tube coming from wall.
  6. Place smaller compression nut and sleeve on supply tube.
  7. Line up shut off valve with stub-out. Engage sleeve and compression nut.
  8. Position valve to receive water supply tube. Tighten compression nut and sleeve.
Iphone8_app_screen

KEENEY CATALOG APP

  • Easily look up and find products
  • Create work lists of favorite products
  • View PDF catalogs and literature
  • Connect with Customer Service