Instructions:
- Turn off water at the tap.
- Remove old S Trap.
- Remove inlet nut A from the J Bend and select 1-1/4 x 1-1/2 or 1-1/2 washer.
- Put 1-1/2 Marvel Connector on Schedule 40 plastic stub-out.
- Put nut A and washer on sink tailpiece.
- Loosen nut B.
- Put Marvel Connector nut C and washer on floor tube. Insert floor tube in connector.
- Adjust floor tube and swivel J Bend to align trap into position.
- Mark tube at point S, as shown. Cut if necessary.
- Place S Trap aside.
- Solvent weld the Marvel Connector to Schedule 40 plastic pipe stub-out. Follow procedure for solvent weld.
- Position S Trap in Marvel Connector Align J Bend with tailpiece.
- Hand tighten nuts A, B and C. Run water to test for leaks.
Note: These parts are designed for a hand-tight installation. Pipe thread compound is not required.
Note: If connecting to a 1-1/4 floor connection, purchase a 1-1/2 x 1-1/4 Reducer Coupling PP55-8 and follow instructions for installation.
Installation hints:
Since it traps items that may fall into the drain and blocks gases from the waste drain system, water and dirt will be present in the existing trap. Place a bucket under the old trap before attempting to remove it.
Solvent weld procedure:
Do not solvent weld any parts until all parts have been test-assembled.
- IMPORTANT: Ask your dealer for the proper solvent weld cement.
- Clean all foreign matter from both mating parts.
- Apply solvent weld cement to both mating parts.
- Join both parts with a twisting motion.